    Goldline Salt Chlorinator Aqua Rite Turbo Cell T-CELL-9
    [T-CELL-9]

    Price:  

    Goldline Salt Water Chlorine Generator Aqua Rite Turbo Cell T-CELL-9

    The Turbo Cells automatically generate a self-renewing supply of fresh, pure chlorine for water that's clean, clear and luxuriously soft.

    T-CELL-9 is forswimming pools up to 25,000 gallonswimming pools.

    Servicing and Cleaning the Aqua Rite cell
    Turn off power to the Aqua Rite before removing the electrolytic cell. Once removed, look inside the cell and inspect for scale formation (light colored crusty or flaky deposits) on the plates and for any debris which has passed through the filter and caught on the plates. If no deposits are visible, reinstall. If deposits are seen, use a high pressure garden hose and try to flush the scale off. If this is not successful, use a plastic or wood tool (do not use metal as this will scratch the coating off the plates) and scrape deposits off of plates. Note that a buildup on the cell indicates that there is an unusually high calcium level in theswimming pool (oldswimming pool water is usually the cause). If this is not corrected, you may to have to periodically clean the cell. The simplest way to avoid this is to bring theswimming pool chemistry to the recommended levels as specified.

    Mild Acid Washing: Use only in severe cases where flushing and scraping will not remove the majority of deposits. To acid wash, turn off power to Aqua Rite. Remove cell from piping. In a clean plastic container, mix a 4:1 solution of water to muriatic acid (one gallon of water to one quart of muriatic acid). ALWAYS ADD ACID TO WATER - NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and appropriate eye protection. The level of the solution in the container should just reach the top of the cell so that the wire harness compartment is NOT submerged. It may be helpful to coil the wiring before immersing the cell. The cell should soak for a few minutes and then rinse with a high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace cell and inspect again periodically.

    Winterizing
    The Aqua Rite electrolytic cell and flow detection switch will be damaged by freezing water just as yourswimming pool plumbing would. In areas of the country which experience severe or extended periods of freezing temperatures, be sure to drain all water from the pump, filter, and supply and return lines before any freezing conditions occur. The electronic control is capable of withstanding any winter weather and should not be removed.

    T-CELL-9 require software revision: Aqua Rite 1.50 or greater.